
12 RUSH Multibeam 2 User Manual
Linking fixtures to power in a chain
If you obtain a 12 AWG or 2.5 mm
2
power input cable and 12 AWG or 2.5 mm
2
throughput cables from Martin™ (see Accessories on page 29), you can relay
mains power from one fixture to another by connecting fixtures to power in a
linked daisy-chain, MAINS OUT throughput socket to MAINS IN input socket.
Using 12 AWG or 2.5mm
2
cables from Martin™, you can link:
• Maximum seven (7) RUSH Multibeam 2 fixtures in total at 100-120 V, or
• Maximum twelve (12) RUSH Multibeam 2 fixtures in total at 200-240 V.
Fixture overview
1 - Display
2 - LEDs
The four LEDs on the rear of the fixture have the following functions:
DMX On Valid DMX signal present
MASTER On Master mode
SLAVE On Slave mode
SOUND Flashing Sound activation (Music trig)
Komentáře k této Příručce